Display |
Large screen dynamic LCD, instantaneous sound level, with analogammeter display |
|
Microphone |
Φ12.7mm (1/2') test condenser microphone |
|
Frequency Range |
10Hz~20,000Hz |
|
Frequency Weighting |
A, C, and Lin(Linear) |
|
Range |
25dB~130dB (A) |
|
Range Control |
Manual, Three Gears, Linear Range>60dB |
|
Testing Range |
30dB~90dB (dynamic scale display 10~100) 50dB~110dB (dynamic scale display 30~120) 70dB~130dB (dynamic scale display 50~140) |
|
Accuracy |
In accordance with IEC61672 standard, class 2 |
|
Time Weighting |
Fast (F), Slow (S), Impulse (I) |
|
Filter |
Built in 1/1 and 1/3 octave filter |
|
Calibration |
Use class 1 sound level calibrator |
|
The Output Interface |
AC signal output USB data cable output |
|
Power Supply |
4x1.5V AAA(UM-4)Battery |
|
External Power |
6V |
|
Size |
227x63x26mm |
|
Weight |
185g (Not Including Batteries) |
|
|
Phone:+8617806256878 |
|
Email:sales@realltech.cn |
|
Address:No.2 Huiying Road, Jiaozhou City, Qingdao City, Shandong Province, China
|
All Rights Reserved 2024 Qingdao Realltech Instruments Co.,Ltd